← All Jobs

ELECTRONIC MEASUREMENT EQUIPMENT MECHANIC (T32)

Army National Guard Units · Department of the Army
📍 Camp Ripley, Minnesota 💰 $35.73 – $41.71/hr

Quick Facts

Similar Open Positions

ELECTRONIC MEASUREMENT EQUIPMENT MECHANIC
Air Force Materiel Command · Tinker AFB, Oklahoma · same category
ELECTRONIC MEASUREMENT EQUIPMENT MECHANIC
Army National Guard Units · Ayer, Massachusetts · same category
Electronic Measurement Equipment Mechanic Leader
U.S. Army Joint Munitions Command · Letterkenny Army Depot, Pennsylvania · same category
TITLE 5 ELECTRONIC MEASUREMENT EQUIPMENT MECHANIC (MI 127th MXG)
Air National Guard Units · Selfridge ANG Base, Michigan · same category
ELECTRONIC MEASUREMENT EQUIPMENT MECHANIC TITLE 32 TEMPORARY NTE 1 NOV 2027
Army National Guard Units · Concord, New Hampshire · same category
ELECTRONIC MEASUREMENT EQUIPMENT MECHANIC (TITLE 32)
Army National Guard Units · Springfield, Illinois · same category

Job Summary

THIS IS AN ARMY NATIONAL GUARD TITLE 32 EXCEPTED SERVICE POSITION UNIT: FMS #9 LOCATION: Camp Ripley, Minnesota SELECTING OFFICIAL: CW3 Jacob Riggs (320)616-3063 ARMY NATIONAL GUARD MEMBERSHIP IS REQUIRED

Key Responsibilities

Major Duties: This is not an all-inclusive list A ELECTRONIC MEASUREMENT EQUIPMENT MECHANIC (T32), WG-2602-11, (1) Calibrates and repairs TMDE within support capability and authority including various levels of calibration as designated in technical bulletins, manuals, etc. Performs functional electronic, physical, and radioactive testing involving interpretation and analysis of measurement data, in accordance with cyclic inspection requirements.

Aligns, troubleshoots, tests, inspects, repairs, modifies, calibrates and certifies precision measurement equipment such as multimeters, microwave equipment, oscilloscopes, temperature analyzers, mercurial barometers, gage blocks and micrometer caliper dimensional equipment, digital voltmeters, signal generators, torque wrenches, pressure gauges, torque testers, weight scales, electronic counters, radiation monitors, radix calibrators, and radiation dosimeters.

Analyzes and isolates component malfunctions; calculates and determines tolerances; and performs tests and calibrations in accordance with instructions, which are often vague and incomplete, and may require the preparation of diagrams and instructions to facilitate the calibration action.

(2) Sets up system test sets and various types of test equipment such as frequency meters, standing wave ratio meters, radio frequency (RF) power meters, function/ arbitrary waveform generator, distortion analyzers, time frequency work stations, oscillators, voltmeters, electronic counters, oscilloscopes, attenuators, decade resistors and capacitors, signal generators, stroboscope, tachometers, pneumatic and hydraulic pressure standards and other physical and electronic tests.

Diagnoses equipment, makes repairs, and replaces defective parts/components such as integrated circuits, printed circuit boards, electronic condition coils, radiation detector boards/circuits, crystals, transistors, tubes, transformers, condensers, diodes, relays potentiometers, and related components. (3) Following repair, tests by applying signals in known amplitude and wave shape into oscilloscopes to observe wave pattern.

Isolates faults by taking measurements and comparisons in voltage, amperage, ohms, henries, power factor, watts, temperature, humidity, microns, foot-pounds, decibels, sensitivity, noise, stability, Voltage Standard Wave Ratio (VSWR), impedance, phase, absolute pressure, time intervals, displacement, flow rate, etc., to determine performance of equipment. If signal is distorted, traces it through electronic stages to locate malfunctioning part.

Checks sweep rate by feeding known signal to an oscilloscope and observing wave pattern to correct shape and size. Operates equipment to complete range checking for proper operation of positioning controls. Adjusts with trimmer potentiometers; and if calibration is still not possible, adds or removes sufficient resistance to permit balancing of circuit. As needed, contacts the using organization to obtain information concerning the nature of the malfunction.

(4) Determines purpose in operation characteristics of each major section. Refers to technical manuals and manufactures specifications to obtain information on operation characteristics of circuit components such as integrated circuits, microprocessors, decoders, latching networks, notch filters, logics, controllers, programmable gain amplifiers, digital displays, transistors, tubes, transformers, coils, relays, motors, and similar devices.

Disassembles, cleans and inspects parts such as printed circuit boards, resistors, capacitors, integrated circuits, relays, chambers, cables, and wiring for evidence or wear or malfunction. Repairs and/or replaces parts as required. Uses special test devices and radioactive samples or other calibrated sources. Tests equipment for sensitivity and correct operation. Observes necessary precautions as stipulated in operational repair manuals.

Makes radiation calculations/readings at various distances from the standard ensuring radiation equipment is operating in specified parameters. (5) Completes necessary Army Maintenance Management System (TAMMS), calibration, radiation reports and other records and forms on work completed. Ensures maximum number of weapons systems are operationally ready.

Uses TMDE Integrated Maintenance Management Systems (TIMMS) for all supported equipment to track, turn-in, repair, calibrate, and return to the end user in a timely fashion to prevent work stoppages. Furnishes technical data to the supervisor for inclusion in reports as well as recommending equipment improvement and solutions for unusual problems related to testing and the use of precision TMDE.

(6) Follows appropriate safety procedures, with special care being exercised while calibrating high voltage, radio frequency, radioactive sources and high-pressure Performs other duties as assigned. The above does not list all duties. The full list of duties can be provided upon request.

Requirements & Education

EDUCATION: NA You must provide transcripts or other documentation to support your Educational claims. To receive credit for Education, you must provide documentation of proof that you meet the Education requirements for this position.

Contact

Tyler.j.stroming.mil@army.mil

Frequently Asked Questions

Which agency is hiring for this position?

This position is with Army National Guard Units, Department of the Army.

What is the salary for this position?

The posted pay range is $35.73 – $41.71/hr.

What security clearance is required?

This position requires a Secret security clearance.

What is the application deadline?

Applications close on 2026-10-20.

Who is eligible to apply?

This position is open under the 'Nguard' hiring path.

Related Searches

ELECTRONIC MEASUREMENT EQUIPMENT MECHANIC (T32), ELECTRONIC MEASUREMENT EQUIPMENT MECHANIC (T32) jobs, ELECTRONIC MEASUREMENT EQUIPMENT MECHANIC (T32) careers, apply ELECTRONIC MEASUREMENT EQUIPMENT MECHANIC (T32), ELECTRONIC MEASUREMENT EQUIPMENT MECHANIC (T32) in Camp Ripley, ELECTRONIC MEASUREMENT EQUIPMENT MECHANIC (T32) jobs Camp Ripley, ELECTRONIC MEASUREMENT EQUIPMENT MECHANIC (T32) in Minnesota, ELECTRONIC MEASUREMENT EQUIPMENT MECHANIC (T32) jobs Minnesota, jobs in Camp Ripley, careers in Camp Ripley, jobs in Minnesota, federal jobs in Minnesota, government jobs Minnesota, jobs near Camp Ripley, Minnesota, Army National Guard Units, Army National Guard Units jobs, Army National Guard Units careers, Army National Guard Units Camp Ripley, Department of the Army, Department of the Army jobs, Electronic Measurement Equipment Mechanic, Electronic Measurement Equipment Mechanic jobs, USAJOBS Electronic Measurement Equipment Mechanic, nguard jobs, Secret clearance jobs

Source: USAJOBS.gov — U.S. Federal Government

Apply on official site →